现货GE CT机型号如下:
Manufacturer : GE
Model : CTe
Year of Manufacturer : 2000
Description :
we have a GE CT scanner Model : CTe
Manufactured in Year 2000
Machine de-installed in Jan 2006
Gantry – rotation on system is 588078
-- sytem slice count is 179161
tube slices on current tube are – 133955 Slices.
Last Tube changed in 2002 due to air bubble problem – the current tube
is in excellent condition.
Options on machine –
- Reformat
- Fast scan 1.0 Sec
- Helical 3D max
- Helical plus
- Power 200ma Max
- Thickness 1 mm
- 3D
- smart addition

Manufacturer : GE
Model : CT Legato DUO
Year of Manufacturer : 1999
Description :
Manufactured in July 1999
Total Gantry Slice:228,072
Tube Slice:63,893
Current tube installed in : 2003 Nov
SYSTEM  Part No. SJAD9145CT
S/N: 20600BZZ00-4060000
Gantry Part No. 2174975
S/N: 469242YM2
Table Part No.2129570
S/N: 323918YM3
Console Part No.2174625
S/N: 469141YM6
Power BOX Part No.2121798
S/N: 586260YM2

Manufacturer : GE
Model : Hispeed CT/I ( Performix tube )
Year of Manufacturer : 1999
Description :
Manufactured: February 1999
Gantry Model: 2183255-2, Serial: 237461CN9
OCTANE Console Computer$B!J(Bincludes Modem Option$B!K(B 48KW
Generator, Global
PDU
HLI Detector-AU/HSA/EMC 6.3 MHU X-Ray Tube (Performix) made in March
2004
Total Rotation: 458524 ; 20$B!I(B Digital Autoscan Color
monitor-2(changed a
month back)
Advantage workstation Version 3.1 running on Ultra10+stations
Voxtool 2.0
DICOM V3.0, Volume Rendering, 0.8 second scan (Sub-Second Scanning), 3D
Analysis , fast Reconstruction, Smart Helical, Smart prep, Smart Beam, ,
Warpscan , 2nd disk option for Octane, LCAM Digital DASM, 128MB UPGR for
Octane, 48.5 Phantom, , 34.9 phantom, xtalk phantom, QA phantom Sonata
RDY,
Non-EMC, F. RHAP, MX200 CT Housing, MX 200 CT Insert, EMC Collimator, ,
Phantom holder, cradle extender, covers, gantry controls, axial head
holder,
manual, software
Deinstalled: 17th September 2005

Manufacturer : GE
Model : GE NXi (Dual slice) CT
Year of Manufacturer : 2001
Description :
System Installed in November 2001
- Gantry Model 2247010 S No 766886YM6 July
2001
- Computer Console Model 2008112 S No 817404YM7 July 2001
- Patient Couch Model 2113694 S No 820056YM0 July 2001
- X-Ray Tube MX165Q3 S No 15705B17
replaced on 22nd June 2004
- Application S/W Hi Speed NXi 5.54 installed on 26 June 2003
- Total Gantry Revolutions 2066986 ( Gantry slices is roughly 1/4 of
slice seconds = 2066986 /4 ~ 516,746 slices on Gantry )
- Slice Sec, on tube 204013 ( tube slices is roughly 1/4
of slice seconds = 204013 /4 ~ 51,000 slices on tube )
-Options Reformat
Remote Tilt
Power 350mA Max.
Fast Scan 0.8 sec.
Extended FOV
Enhance Config
Helical 60 Max.
Image Disk
Raw Data 1000 Max
3D
Smart Prep
The system was in perfect scanning condition and a no. of scans were
performed on phantoms before Deinstallation.
There is a complete set of manuals, phantoms and system S/W with the
scanner
and packed separately in marked boxes.

近期下线机型号如下:
2002 GE Light
Speed Avail
Jan MO DS
2003 GE Light Speed Ultra
8 Avail Now
2002 GE Light Speed Ultra 8
Mobile Avail Now
2002 GE Hi Speed ZXI
Avail Jan NY P14217
2002 GE Hi Speed NXI
Base Avail Feb
NY S1054501
2000 GE Light Speed QXI
Avail Dec MN S10181
2001 GE Hi Speed DXI
Mobile Avail Now
PA All
|